Technolite Extra

Technolite Extra

STONE WOOL

General Building

PRODUCT DESCRIPTION
TECHNOLITE EXTRA are non-combustible, hydrophobic thermal and sound insulation boards, made of stone wool.

APPLICATION
As a layer for thermal, acoustic and fire insulation in general building, where the insulation does not bear the external load (framed partitions and floors, attic floors, pitched roofs with the rafter system, etc.). Also used as the first (internal) insulation layer in two-layer thermal insulation systems of ventilated facades.

THICKNESS RANGE 50 – 300 [mm]

DLACZEGO WARTO WYBRAĆ PŁYTY TECHNOFACADE 34?

  • Materiał charakteryzuje się wspołczynnikiem przewodzenia ciepła λ (lambda) o wartości 0,034 W/mK
  • Włókna te są rownież bardzo odporne mechanicznie co znajduje potwierdzenie w parametrach wytrzymałościowych CS (ściskanie) wynosi 20 kPa oraz TR (rozrywanie) wynosi 10 kPa
  • TECHNOFACADE 34 zapewnia rownież najwyższą klasę paroprzepuszczalności
  • Najwyższa klasy reakcji na ogień według europejskiej klasyfikacji ogniowej
  • Materiał wyprodukowany w Polsce
Logistics information

Full truck loading: 22 standard pallets / 11 pallets marked with H2,6

Storage

The product may only be stored outdoors in an intact, originally packed pallet. Protected against the harmful effects of weather conditions and set on a dry and stable surface. Maximum stacking height of pallets up to three meters.

Additional indications on the label

H2,6 – pallet with a height of about 2,6 m / twice the amount of the product compared to a standard pallet

(PILLAR) –  product on a stone wool base instead of a wooden pallet

(X slabs) – number of slabs in the pack

(N) / (S) – code of the region

Certificate number: 1454-CPR-0292

Designation code: MW-EN 13162-T4-DS(70,90)-CS(10)0,5-AFr5-WS-WL(P)-MU1

Declaration of performance no: TNI/GB/TLE/2023_03

DECLARED PARAMETERS

Technolite Extra DECLARED PARAMETERS
ParameterSymbolUnitValueMethod
Declared thermal conductivityλDW/mK0,035EN 12667, EN 12939
Thickness tolerance classT-T4EN 823
Dimensional stability under certain temperature and humidity conditionsDS(70,90)%≤1EN 1604
Compressive stress at 10% deformationCS(10)kPa≥ 0,5EN 826
Tensile strength perpendicular to the facesTRkPaNPDEN 1607
Point load at 5 mm deformationPL(5)NNPDEN 12430
Air flow resistivityAFrkPa·s/m25EN 9053-1
Short-term water absorptionWSkg/m2≤ 1EN 29767
Long-term water absorptionWL(P)kg/m2≤ 3EN 16535
Water vapor diffusion resistance coefficientMU-MU1EN 13162+A1
Reaction to fireRtF-A1EN 13501-1, EN 15715
Characteristic self-weight loadgkN/m30,4-

NPD - No Performance Declared

DECLARED THERMAL REISTANCE

Value of declared thermal resistance RD
Thickness [mm]102030405060708090100110120130140150
RD [m²K/W]----1,351,651,952,202,502,803,053,353,653,954,20
Thickness [mm]160170180190200210220230240250260270280290300
RD [m²K/W]4,504,805,055,355,655,956,206,506,807,057,357,657,958,208,50

DECLARED THERMAL REISTANCE

DECLARED THERMAL REISTANCE Technolite

STANDARDOWE WYMIARY I PAKOWANIE

Pełna nazwaGrubośćDługośćSzerokośćFormat paletyPaletaPaletaPłyt na paleciePaczek na paleciePaczkaPaczkaPłyt w paczce
[mm][mm][mm][mm][m³][m²][-][-][m³][m²][-]
1200x600x50 (6 slabs)5012006002400x12003,456069,1296160,21604,326
1200x600x60 (5 slabs)6012006002400x12003,456057,6080160,21603,605