Technolite

BOERNER TOP 80

Flat roofs

Stone Wool

PRODUCT DESCRIPTION
BOERNER TOP 80 are non-combustible, hydrophobic thermo and sound
insulation boards with a disturbed fiber arrangement, made of stone wool.

APPLICATION

Thermal, acoustic and non-combustible insulation in industrial and civil
construction. Intended for use in construction facilities as a top layer of a
two-layer roof thermal insulation system in combination with
BOERNER BASE slabs or in other single- or multi-layer insulation
systems.

THICKNESS RANGE 20-120 [mm]

LOGISTICS INFORMATION

Standard packaging on pillars. Full truck loading: 22 standard pallets.
Packing on wooden pallets (22 pallets and 11 high pallets marked with H2.6) to be confirmed in the logistics department

STORAGE

The product may only be stored outdoors in an intact, originally packed pallet. Protected against the harmful effects of weather conditions and set on a dry and stable surface. Maximum stacking height of pallets up to three meters.

ADDITIONAL INDICATIONS ON THE LABEL

H2,6 – pallet with a height of about 2,6 m / twice the amount of the product compared to a standard pallet

(PILLAR) –  product on a stone wool base instead of a wooden pallet

(X slabs) – number of slabs in the pack

Certificate number: 1454-CPR-0292

Designation code for thickness products <50mm
MW-EN 13162-T5-DS(70,90)-CS(10)80-TR15-PL(5)700-WS-WL(P)-MU1
Designation code for thickness products ≥50mm
MW-EN 13162-T5-DS(70,90)-CS(10)80-TR15-PL(5)800-WS-WL(P)-MU1

Declaration of performance no: BRI/FR/BRT80/2024_04

DECLARED PARAMETERS

Technoroof TOP 80 DECLARED PARAMETERS
>-
ParameterSymbolUnitValueMethod
Declared thermal conductivityλDW/mK0,039EN 12667, EN 12939
Thickness tolerance classT-T5EN 823
Dimensional stability under certain temperature and humidity conditionsDS(70,90)%≤ 1EN 1604
Compressive stress at 10% deformationCS(10)kPa≥ 80EN 826
Tensile strength perpendicular to the facesTRkPa≥ 15EN 1607
Point load at 5 mm deformation <50mmPL(5)N≥ 700EN 12430
Point load at 5 mm deformation ≥50mmPL(5)N≥ 800EN 12430
Air flow resistivityAFrkPa·s/m2NPDEN 9053-1
Short-term water absorptionWSkg/m2≤ 1EN 29767
Long-term water absorptionWL(P)kg/m2≤ 3EN 16535
Water vapor diffusion resistance coefficientMU-MU1EN 13162+A1
Reaction to fireRtF-A1EN 13501-1, EN 15715

NPD - No Performance Declared

DECLARED THERMAL RESISTANCE

Value of declared thermal resistance RD
Thickness [mm]102030405060708090100110120130140150
RD [m²K/W]-0,500,751,001,251,501,752,052,302,552,803,05---
Thickness [mm]160170180190200210220230240250260270280290300
RD [m²K/W]---------------

DECLARED THERMAL RESISTANCE

Technoroof TOP 80 DECLARED THERMAL RESISTANCE