BOERNER TOP 70 TAPERED
Flat roofs
Stone Wool
PRODUCT DESCRIPTION
EBOERNER TOP 70 TAPERED are non-combustible, hydrophobic stone
wool boards with a disturbed fiber arrangement, for shaping slopes and
counter-slopes on flat roofs.
APPLICATION
Shaping slopes that drain water from flat roofs to roof drains.
BOERNER TOP 70 TAPERED boards are placed on the BOERNER TOP
thermal insulation layer. Boards with an inclination of 2.5% and 3.0% are
available for shaping slopes and with an inclination of 5% for making
counter-slopes.
THICKNESS RANGE 10-70 [mm]
Full truck loading: 52 standard pallets
The product may only be stored outdoors in an intact, originally packed pallet. Protected against the harmful effects of weather conditions and set on a dry and stable surface. Maximum stacking height of pallets up to three meters.
H2,6 – pallet with a height of about 2,6 m / twice the amount of the product compared to a standard pallet
(PILLAR) – product on a stone wool base instead of a wooden pallet
(X slabs) – number of slabs in the pack
Certificate number: 1454-CPR-0292
Designation code: MW-EN 13162-T5-DS(70,90)-CS(10)70-TR15-PL(5)700-WS-WL(P)-MU1
Declaration of performance no: BRI/FR/BRT70T/2023_04
DECLARED PARAMETERS
Parameter | Symbol | Unit | Value | Method |
---|---|---|---|---|
Declared thermal conductivity | λD | W/mK | 0,039 | EN 12667, EN 12939 |
Thickness tolerance class | T | - | T5 | EN 823 |
Dimensional stability under certain temperature and humidity conditions | DS(70,90) | % | ≤ 1 | EN 1604 |
Compressive stress at 10% deformation | CS(10) | kPa | ≥ 70 | EN 826 |
Tensile strength perpendicular to the faces | TR | kPa | ≥ 15 | EN 1607 |
Point load at 5 mm deformation | PL(5) | N | ≥ 700 | EN 12430 |
Air flow resistivity | AFr | kPa·s/m2 | NPD | EN 9053-1 |
Short-term water absorption | WS | kg/m2 | ≤ 1 | EN 29767 |
Long-term water absorption | WL(P) | kg/m2 | ≤ 3 | EN 16535 |
Water vapor diffusion resistance coefficient | MU | - | MU1 | EN 13162+A1 |
Reaction to fire | RtF | - | A1 | EN 13501-1, EN 15715 |
NPD - No Performance Declared
DECLARED THERMAL RESISTANCE
Value of declared thermal resistance RD | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 130 | 140 | 150 |
RD [m²K/W] | 0,25 | 0,50 | 0,75 | 1,00 | 1,25 | 1,50 | 1,75 | - | - | - | - | - | - | - | - |
Thickness [mm] | 160 | 170 | 180 | 190 | 200 | 210 | 220 | 230 | 240 | 250 | 260 | 270 | 280 | 290 | 300 |
RD [m²K/W] | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |