Technolite

BOERNER VENT

Ventilated facades

Stone Wool

PRODUCT DESCRIPTION
BOERNER VENT are non-combustible, hydrophobic thermal and acoustic
insulation boards with a disturbed fiber arrangement, made of stone wool.
Increased physical and mechanical parameters ensure reliable use of the
material in vertical structures.

APPLICATION
As a layer of thermal and acoustic insulation in ventilated systems with
various types of external cladding and in frame walls.

THICKNESS RANGE 50-200 [mm]

LOGISTICS INFORMATION

Full truck loading: pallets marked with H2,6

STORAGE

The product may only be stored outdoors in an intact, originally packed pallet. Protected against the harmful effects of weather conditions and set on a dry and stable surface. Maximum stacking height of pallets up to three meters.

ADDITIONAL INDICATIONS ON THE LABEL

H2,6 – pallet with a height of about 2,6 m / twice the amount of the product compared to a standard pallet

(PILLAR) –  product on a stone wool base instead of a wooden pallet

(X slabs) – number of slabs in the pack

Certificate number: 1454-CPR-0292
Designation code: MW-EN 13162-T5-DS(70,90)-CS(10)0,5-AFr5-WS-WL(P)-MU1
Declaration of performance no: BRI/VF/BRV/2023_04

DECLARED PARAMETERS

Technovent DECLARED PARAMETERS
ParameterSymbolUnitValueMethod
Declared thermal conductivityλDW/mK0,034EN 12667, EN 12939
Thickness tolerance classT-T5EN 823
Dimensional stability under certain temperature and humidity conditionsDS(70,90)%≤ 1EN 1604
Compressive stress at 10% deformationCS(10)kPa≥ 0,5EN 826
Tensile strength perpendicular to the facesTRkPaNPDEN 1607
Point load at 5 mm deformationPL(5)NNPDEN 12430
Air flow resistivityAFrkPa·s/m25EN 9053-1
Short-term water absorptionWSkg/m2≤ 1EN 29767
Long-term water absorptionWL(P)kg/m2≤ 3EN 16535
Water vapor diffusion resistance coefficientMU-MU1EN 13162+A1
Reaction to fireRtF-A1EN 13501-1, EN 15715

NPD - No Performance Declared

DECLARED THERMAL RESISTANCE

Value of declared thermal resistance RD
Thickness [mm]102030405060708090100110120130140150
RD [m²K/W]----1,401,702,002,302,552,853,153,453,754,054,35
Thickness [mm]160170180190200210220230240250260270280290300
RD [m²K/W]4,654,955,205,505,80----------

DECLARED THERMAL RESISTANCE

Technovent DECLARED THERMAL RESISTANCE