BOERNER VENT EXTRA FB
Ventilated facades
Stone Wool
PRODUCT DESCRIPTION
BBOERNER VENT EXTRA FB are non-combustible, hydrophobic thermal
and acoustic insulation boards with a disturbed fiber arrangement, made
of stone wool, covered on one side with a black glass veil. Increased
physical and mechanical parameters ensure reliable use of the material in
vertical structures.
APPLICATION
As an external layer of thermal and acoustic insulation in ventilated
systems with various types of external cladding and in frame walls. The
glass veil layer additionally strengthens the board surface and protects
against air being blown out of the mineral wool space.
THICKNESS RANGE 100-200 [mm]
Full truck loading: 11 pallets marked with H2,6
The product may only be stored outdoors in an intact, originally packed pallet. Protected against the harmful effects of weather conditions and set on a dry and stable surface. Maximum stacking height of pallets up to three meters.
H2,6 – pallet with a height of about 2,6 m / twice the amount of the product compared to a standard pallet
(PILLAR) – product on a stone wool base instead of a wooden pallet
(X slabs) – number of slabs in the pack
Certificate number: 1454-CPR-0292
Designation code: MW-EN 13162-T5-DS(70,90)-CS(10)0,5-AFr5-WS-WL(P)-MU1
Declaration of performance no: BRI/VF/BRVEFB/2023_04
DECLARED PARAMETERS
Parameter | Symbol | Unit | Value | Method |
---|---|---|---|---|
Declared thermal conductivity | λD | W/mK | 0,034 | EN 12667, EN 12939 |
Thickness tolerance | T | - | T5 | EN 823 |
Dimensional stability under specified temperature and humidity conditions | DS(70,90) | % | ≤ 1 | EN 1604 |
Compressive stress at 10% deformation | CS(10) | kPa | ≥ 0,5 | EN 826 |
Tensile strength perpendicular to the faces | TR | kPa | NPD | EN 1607 |
Point load at 5 mm deformation | PL(5) | N | NPD | EN 12430 |
Air flow resistivity | AFr | kPa·s/m² | 5 | EN 9053-1 |
Short-term water absorption | WS | kg/m² | ≤ 1 | EN 29767 |
Long-term water absorption by partial immersion | WL(P) | kg/m² | ≤ 3 | EN 16535 |
Water vapor diffusion resistance factor | MU | - | MU1 | EN 13162+A1 |
Reaction to fire | RtF | - | A1 | EN 13501-1, EN 15715 |
NPD - No Performance Declared
DECLARED THERMAL RESISTANCE
Values of declared thermal resistance RD | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 130 | 140 | 150 |
RD [m²K/W] | - | - | - | - | - | - | - | - | - | 2,85 | 3,15 | 3,45 | 3,75 | 4,05 | 4,35 |
Thickness [mm] | 160 | 170 | 180 | 190 | 200 | 210 | 220 | 230 | 240 | 250 | 260 | 270 | 280 | 290 | 300 |
RD [m²K/W] | 4,65 | 4,95 | 5,20 | 5,50 | 5,80 | - | - | - | - | - | - | - | - | - | - |